LiTec with lock

LiTec without lock

LiTec Series – Dry break couplings
Available in two versions:
- as a standard coupling system with a lock or as
- dispenser/receiver system for oil/water and fuel application where locking of the coupling is not intended.
Lightweight, small-sized and high-pressure qualified quick connect and disconnect couplings for hydraulic, pneumatic fuel and other applications.
- Dry Break System, no spillage
- Valved male and valved female end
- One-hand operation, push-pull operating system
- Totally covered and sealed mechanism
- Correct locked condition control
Material:
Body and valves anodized aluminum alloy EN AW-7075
Male housing hc, locking parts, bolt and springs stainless steel 1.4305
Seals:
FPM (Flourcarbon, Viton®)
EPDM (Ethylene-Propylene-Dien-Rubber)
(other elastomers on request)
Operating pressure:
150 bar / 2200 psi
Burst pressure:
Min. 450 bar / 6500 psi (also for the disconnected valves)
Operating temperatures depending on sealing material:
FPM: -20°C to +200°C
EPDM: -50°C to +150°C
LiTec Series with lock
The QDV couplings in this section all have a lock.

Coupler Standard -08/-08

Coupler Bulk -08/-08
Coupler -08 – with lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8040 | Standard | FPM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8041 | Standard | EPDM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8061 | Bulk | EPDM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |

Coupler Standard-06/-08

Coupler Standard-06/-06

Coupler Bulk -06/-06
Coupler -06 – with lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8042 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8043 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 6040 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6041 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6060 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6061 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |

Nipple Standard -08/-08

Nipple Bulk -08/-08
Nipple -8 – with lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8020 | Standard | FPM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8021 | Standard | EPDM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8030 | Bulk | FPM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8031 | Bulk | EPDM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |

Nipple Standard -06/-08

Nipple Bulk -06/-08

Nipple Standard -06/-06

Nipple Bulk -06/-06
Nipple -6 – with lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8023 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8022 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8032 | Bulk | FPM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8033 | Bulk | EPDM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 6020 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6021 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6030 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6031 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |

Dustcap with lanyard
Dustcap with lanyard for nipple with lock
Article-no. | Seal | Body | Lock |
Z-Q 0001 8102 | FPM | -08 | with lock |
Z-Q 0001 6100 | FPM | -06 | with lock |
Overview LiTec with lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8040 | Standard | FPM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8041 | Standard | EPDM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8060 | Bulk | FPM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8061 | Bulk | EPDM | -08 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8042 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 8043 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Coupler | with lock |
Z-Q 0001 6040 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6041 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6060 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 6061 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Coupler | with lock |
Z-Q 0001 8020 | Standard | FPM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8021 | Standard | EPDM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8030 | Bulk | FPM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8031 | Bulk | EPDM | -08 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8023 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8022 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8032 | Bulk | FPM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 8033 | Bulk | EPDM | -06 | 3/4 – 16 UNF (-08) | Nipple | with lock |
Z-Q 0001 6020 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6021 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6030 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
Z-Q 0001 6031 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Nipple | with lock |
LiTec Series without a lock
The QDV couplings listed below all have a no lock. For applications where locking is not intended.

Dispenser Standard -06/-06
Dispenser -6 – without lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8046 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Dispenser | without lock |

Receiver Standard -06/-08

Receiver Bulk -06/-08

Receiver Standard -06/-06

Receiver Bulk -06/-06
Receiver -6 – without lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8024 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8025 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8034 | Bulk | FPM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8035 | Bulk | EPDM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 6022 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6023 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6024 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6025 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Overview LiTec without lock
Article-no. | Variant | Seal | Body | Thread | Part | Lock |
Z-Q 0001 8046 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Dispenser | without lock |
Z-Q 0001 8024 | Standard | FPM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8025 | Standard | EPDM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8034 | Bulk | FPM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 8035 | Bulk | EPDM | -06 | 3/4 – 16 UNF (-08) | Receiver | without lock |
Z-Q 0001 6022 | Standard | FPM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6023 | Standard | EPDM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6024 | Bulk | FPM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |
Z-Q 0001 6025 | Bulk | EPDM | -06 | 9/16 – 18 UNF (-06) | Receiver | without lock |